4. Connect the negative (black) terminals of the batteries as described below (and shown in
the figure below).
a. Connect the middle connector of the black wire to the negative (black) terminal of
battery B2.
b. If required, connect the other connectors of the black wire to the negative (black)
terminals of batteries B1 and B3.
5. Connect the positive (red) terminals of the batteries as described below (and shown in the
figure below).
a. Connect the middle connector of the red wire to the positive (red) terminal of battery
B2.
b. If required, connect the other connectors of the red wire to the positive (red) terminals
of batteries B1 and B3.